Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany
  • Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany,MY SHOP,Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany
  • Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany,MY SHOP,Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany

Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany

Download
View all downloads
  • Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany,MY SHOP,Endress+Hauser Proline Promag 53W Electromagnetic Flow Meter, Germany

Description

Endress+Hauser (E+H), Germany Proline Promag 53W Electromagnetic Flowmeter – Detailed Description

I. Product Positioning

Promag 53W is a large‑diameter electromagnetic flow measuring system developed by E+H specifically for drinking water, municipal wastewater and water conservancy & water‑utility industries. It consists of Promag W sensor and Promag 53 high‑accuracy transmitter, supporting compact and remote mounting versions. Compliant with DVGW and ISO pipeline standards, it holds KTW/WRAS/NSF drinking‑water certifications. It is the standard high‑precision metering instrument for water‑plant pipe networks, pump stations and main pipelines of wastewater treatment plants.

II. Measuring Principle

Based on Faraday’s law of electromagnetic induction: conductive liquid cuts the magnetic field to generate induced voltage. Electrodes collect signals, and the transmitter converts them into volumetric flow. There are no internal moving parts or throttling components, bringing zero pressure loss throughout operation. It features energy‑saving, maintenance‑free performance and strong resistance to pipeline vibration interference.

Minimum medium conductivity requirement: ≥5 μS/cm for conventional wastewater; ≥20 μS/cm for softened purified water.

III. Core Specifications

Size range: DN25~DN2000 (1 inch~78 inches), covering small‑and‑medium‑size pipelines up to extra‑large municipal trunk lines. Measuring accuracy: ±0.2 % of reading (top‑tier accuracy for water‑industry applications, applicable for custody‑transfer metering). Medium temperature: ‑20~+80 ℃; optional high‑temperature version with PFA liner for up to 180 ℃. Process pressure: PN6/PN10/PN16/PN40; ANSI Class 150/300 flanges optional. Flow range: maximum 110000 m³/h, bidirectional flow measurement, built‑in bidirectional totalizer.

Ingress Protection Sensor: IP68 (long‑term underwater submersion) Transmitter housing: IP67/NEMA4X; remote wall‑mounted transmitter adopts the same protection rating.

Power supply: 85~260V AC / 16~62V DC; intrinsically‑safe explosion‑proof version: 9~24V DC.

IV. Liner and Electrode Materials (Water‑utility Dedicated)

Liners

‑ Hard rubber: for drinking water and ambient‑temperature wastewater, full drinking‑water certifications obtained, wear‑resistant and anti‑scaling. ‑ Polyurethane (PU): for sediment‑laden, mildly abrasive wastewater and sludge mixtures. ‑ PFA: for high‑temperature and mildly corrosive process water.

Electrodes

‑ 316L stainless steel: general‑purpose for clean water and municipal wastewater. ‑ Hastelloy C: for weak acid‑alkali media and industrial wastewater. ‑ Titanium electrode: for seawater and high‑chloride wastewater.

V. Core Functions of Promag 53 Transmitter

Touch‑control operation without opening housing: external touch keys enable parameter configuration in hazardous areas without opening the enclosure. The 4‑line backlit large‑screen displays flow rate, totalized value and fault information.

Multi‑channel I/O Signals ‑ Analog: 4‑20 mA with HART standard output. ‑ Pulse / frequency output, two‑channel relay alarm outputs, status input.

Rich industrial fieldbus options: HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, seamlessly interfacing with DCS and water‑utility SCADA systems.

Optional Software Function Packages ‑ ECC automatic electrode cleaning program, suitable for scaling‑prone wastewater. ‑ EPD empty‑pipe detection, preventing false metering under no‑medium conditions. ‑ Pulsating flow compensation, batch dosing metering, advanced NAMUR self‑diagnostics.

Intelligent diagnostics: real‑time monitoring of electrode scaling, liner damage, empty‑pipe status and cable faults with early‑warning alerts. Data is permanently stored for traceability.

VI. Communication and Explosion‑proof Certifications

HART is supplied as standard; various fieldbuses are optional. Explosion‑proof approvals: ATEX, IECEx, NEPSI, FM for intrinsic safety / flameproof protection, applicable for hazardous zones in chemical and wastewater plants. Compliance: CE, EAC, drinking‑water certifications KTW/WRAS/ACS/NSF for environmental metering.

VII. Product Construction Versions

‑ Compact version: transmitter mounted directly on top of the sensor, for short pipelines and small‑bore piping in pump houses. ‑ Remote version (mainstream): sensor buried / submerged; transmitter wall‑mounted in control room. Maximum cable length: 50 m. Preferred for municipal buried pipe networks and submerged channel chambers.

VIII. Core Advantages

‑ Water‑utility standardized face‑to‑face flange dimensions complying with DVGW drinking‑water industry standards. Replacement of old flowmeters requires no pipeline modification. ‑ IP68 fully‑waterproof sensor, supporting long‑term buried and underwater installation, resistant to rain immersion. ‑ Zero pressure loss, no wearing parts, no consumable components; multi‑year maintenance‑free operation. ‑ High accuracy of ±0.2 % of reading, satisfying requirements for water‑plant custody transfer and environmental discharge metering. ‑ Complete self‑diagnostics plus electrode‑cleaning software ensures stable operation for high‑sediment and scaling‑prone wastewater. ‑ Modular design: fieldbus upgrade and additional function packages can be enabled without replacing the whole instrument.

IX. Typical Application Scenarios

Inlet / outlet main pipelines of municipal waterworks, flow metering for urban distribution networks, influent & effluent measurement for wastewater treatment plants, pump‑station flow monitoring, pipelines matched for river open channels, seawater desalination, plant‑site circulating‑water systems and water‑conservancy diversion projects.

X. Matching Accessories

Dedicated remote‑installation signal cable, explosion‑proof junction box, pipeline grounding ring, electrode‑cleaning assembly, HART handheld communicator, wall‑mount bracket, original spare parts for liner / electrode.

XI. Supply Information

Standard units with rubber liners in DN50~DN600 are available from stock. Extra‑large sizes DN800 and above, high‑temperature PFA liners, Hastelloy‑C electrodes and complete remote explosion‑proof assemblies are ordered directly from German original manufacturer. Accurate quotations can be provided according to actual medium, pressure, communication and hazardous‑area operating conditions.