APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning

APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning

Download
View all downloads
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning
  • APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning,MY SHOP,APC by Schneider Electric – Schneider APC Precision Temperature and Humidity Air Conditioning

Description

APC by Schneider Electric Complete Product Specification for Precision Constant‑Temperature & Humidity Air‑Conditioners

I. Brand Overview

APC belongs to Schneider Electric. Its Uniflair precision cooling portfolio is a global benchmark for data‑center thermal management. The complete product ecosystem integrates seamlessly with APC UPS, cabinets, PDUs and NetBotz environmental monitoring to deliver an all‑in‑one solution. Engineered for 7×24‑hour non‑stop critical loads, it differs from commercial comfort‑type air‑conditioners. Five core strengths include high‑precision temperature‑humidity control, high sensible‑heat ratio, year‑round continuous operation, modular redundancy and end‑to‑end intelligent monitoring. Temperature control accuracy reaches ±0.5 ℃ and humidity control accuracy ±3% RH. It covers edge computer rooms, small‑to‑medium‑sized computer rooms, high‑density computing‑power IDCs, micro‑module data centers, laboratories and energy‑storage battery cabins.

II. Four Complete Product Lines (Classified by Deployment Architecture)

(1) Amico Small Room‑level Precision Air‑Conditioner (Edge Sites / Base Stations / Power Distribution Rooms)

Key Parameters Cooling capacity: 5 kW‑20 kW; single‑phase 220 V / three‑phase 380 V; R410A eco‑friendly refrigerant. Available in cooling‑only and constant‑temperature‑and‑humidity versions; upflow / downflow air supply optional. Models: SUA0151ACC, SDA0351ACH

Key Features Compact vertical cabinet with small footprint, suitable for 5G base stations, bank branches, small UPS battery rooms and laboratories. Standard configuration includes electric heater, electrode humidifier and independent dehumidification circuit with PID coordinated temperature‑humidity regulation. Wide‑range outdoor unit delivers stable cooling from ‑15 ℃ to +45 ℃; no auxiliary heating required for low‑temperature northern environments. 7‑inch Chinese‑language touch screen, local fault self‑diagnosis, Modbus support for environmental‑monitoring integration. Full‑front maintenance; filters, humidifier trays and compressors are serviceable without side‑access aisles.

(2) Uniflair Leonardo TUAR / TDAR Medium‑to‑large Room‑level Computer‑room Air‑Conditioner (Mainstream for Traditional IDCs)

Cooling range: 23 kW‑168 kW; dual cold‑source options: air‑cooled DX direct expansion and chilled‑water CW.

Mainstream Models ‑ TUAR Air‑cooled Series: TUAR0611, TUAR0922, single / dual scroll compressors with optional N+1 redundancy. ‑ TDAR Chilled‑water Series: TDAR0721, TDAR2202. Compatible with large‑park chilled‑water plants for higher annual energy efficiency.

Core Hardware Configuration High‑sensible‑heat V‑shaped evaporator: optimised for sensible‑heat‑dominated IT equipment load, reducing energy consumption for dehumidification‑reheat and saving over 25 % power annually. EC infinitely variable‑speed fans: airflow dynamically follows computer‑room load, greatly lowering fan power consumption under partial load. Standard electrode humidification system; infrared humidification available as option for stable long‑term operation with tap‑water. EEV electronic expansion valve precisely regulates refrigerant flow to minimise temperature‑humidity fluctuation. Multi‑unit group control; one controller can link up to 99 units for balanced load distribution. Full air‑supply options: upflow, downflow, horizontal side‑blow and under‑floor plenum downflow.

(3) InRow Row‑level Precision Air‑Conditioner (High‑density Cabinets / Micro‑module Computer Rooms)

Product series: InRow RD air‑cooled, InRow RC chilled‑water, InRow RP constant‑temperature‑and‑humidity variant. Cooling capacity: maximum 70 kW per unit; cabinet widths 300 mm / 600 mm. Installed directly between server cabinets within hot‑cold aisles. Representative model: ACFD12‑B air‑cooled row‑level unit.

Core Advantages Proximity cooling eliminates hot‑spots; short hot‑cold‑aisle circulation avoids hot‑cold air mixing. Supports high‑density GPU computing servers with 8‑30 kW per cabinet. Modular on‑demand expansion enables phased investment matching incremental computer‑room construction. Four independent modules for cooling / heating / humidification / dehumidification; RP model delivers full constant‑temperature‑and‑humidity performance. Isolated cooling‑loop design with separate water‑circuit compartment to prevent IT‑equipment flooding caused by water leakage. Top‑and‑bottom bidirectional water‑pipe interfaces; installation feasible with or without raised floor. Comprehensive operating efficiency improved by 30‑50 % compared with conventional room‑type air‑conditioners.

(4) Rack‑mount Cooling (Single‑cabinet / Edge Micro‑module)

Integrated in‑cabinet cooling unit for small‑scale edge data centers with one or two cabinets, retail branches and remote monitoring computer rooms. Cooling capacity 5‑15 kW, built inside standard NetShelter cabinets. No dedicated air‑conditioner room required. Delivered as a complete package with APC micro‑modules.

III. General Core Constant‑Temperature & Humidity System

Refrigeration Circuit Hermetic scroll compressors, variable‑frequency option available. Electronic expansion valve dynamically adjusts refrigerant flow to avoid over‑cooling or over‑heating. R410A low‑GWP eco‑friendly refrigerant complies with green data‑center standards.

Staged Electric Heating Multi‑stage PID stepless temperature regulation. Fast temperature rise under low‑temperature conditions without local overheating; accurate temperature compensation after dehumidification.

Two Humidification Options ‑ Standard electrode humidification (cost‑effective). ‑ Infrared humidification (less limescale, longer maintenance interval, suitable for poor‑quality‑water regions).

Independent Deep Dehumidification Logic Evaporator temperature drops for dehumidification while fan speed is synchronously adjusted together with reheat compensation. Temperature will not plummet during dehumidification, stably maintaining computer‑room standard humidity of 40‑55 % RH.

Air‑supply & Filtration System Standard EU4 medium‑efficiency filter; EU7 high‑efficiency filter optional. Protects heat‑coils from dust accumulation and extends equipment service life.

IV. Core Intelligent Control & Digital Capabilities

Unified Monitoring via NetBotz / StruxureWare Built‑in network management card supports SNMP, Modbus TCP/RTU for integration into Schneider DCIM environmental‑monitoring platform. Real‑time collection of temperature‑humidity, compressor, fan, humidification, fault code and energy‑consumption data.

Multi‑level Fault Early Warning Local audible‑visual alarm; remote alert push via SMS / email. Time‑stamped fault storage covering filter clogging, high pressure, low pressure, humidification failure and fan abnormality.

Group‑control & Load Balancing Multiple units automatically share thermal load; idle units sleep for energy saving. Faulty units are automatically taken offline while remaining units increase cooling capacity to prevent computer‑room outage.

Full‑cycle Self‑check Power‑on self‑test and cyclic runtime self‑check. Monitors compressor, fan, humidification circuit and sensor‑line faults for early prediction of component ageing.

V. Core Technical Advantages

‑ End‑to‑end Schneider Ecosystem: Air‑conditioners, UPS, cabinets, PDUs and environmental‑monitoring from single vendor with unified O&M platform, eliminating third‑party‑interface compatibility risks. ‑ Hierarchical Flexible Selection: Amico for edge sites, Leonardo room‑level for standard computer rooms, InRow row‑level for high‑density computing, rack‑mount cooling for single‑cabinet deployments, covering all computer‑room scales. ‑ Superior Continuous‑operation Reliability: 10‑year design service life. Compressors and fans support N+1 redundancy; single‑component faults will not interrupt computer‑room cooling. ‑ Full‑front Tool‑free Maintenance: Filters, humidifier trays, electric controls and compressors are all serviceable from front side. No side‑maintenance‑aisle required, improving computer‑room space utilisation. ‑ Wide‑range Environmental Adaptability: Outdoor units start at ‑15 ℃ and run stably at +45 ℃, adapting to cold northern winters and hot southern summers. ‑ Modular Expandability: Both row‑level and room‑level units can be added later without full‑capacity upfront investment, lowering initial capital expenditure.

VI. Main Application Industries

‑ Digital Infrastructure: Large‑scale cloud IDCs, AI computing‑power computer rooms, 5G edge base stations, operator switching computer rooms, micro‑module data centers. ‑ Finance & Power: Bank core computer rooms, substation main‑control rooms, energy‑storage‑battery constant‑temperature cabins. ‑ Scientific‑research Laboratories: Metrology‑calibration laboratories, semiconductor inspection rooms, precision‑instrument constant‑temperature laboratories. ‑ Industrial Manufacturing: Lithium‑battery‑production‑line control rooms, precision‑machining control rooms, constant‑temperature zones in clean workshops. ‑ Transportation & Healthcare: Rail‑transit signal computer rooms, hospital imaging computer rooms, ICU isolated power‑distribution rooms.

VII. List of Matching Accessories

Cooling Accessories: Air‑cooled outdoor condensers, chilled‑water plate heat‑exchangers, glycol‑cooled units. O&M Accessories: Spare G4 / EU7 filters, humidifying electrodes / infrared humidifier trays, condensate pumps. Monitoring Accessories: Network‑management cards, NetBotz temperature‑humidity sensors, DCIM monitoring software. Installation Kits: Unit bases, air‑supply ducts, downflow air‑supply plenum boxes, water‑circuit shock‑absorbing connectors.

VIII. Supply Information

Small‑capacity 5‑20 kW Amico units are available from local stock. Conventional air‑cooled TUAR / TDAR room‑level units have sufficient inventory. InRow row‑level units, large chilled‑water units and variable‑frequency modular models are subject to original‑manufacturer production scheduling. Accurate type‑selection and quotation can be provided according to computer‑room area, cabinet heat density, cold‑source type (air‑cooled / chilled‑water) and constant‑temperature‑and‑humidity requirements.