ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter

ABB ACS580-01-026A-4 General Purpose Inverter

Download
View all downloads
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter
  • ABB ACS580-01-026A-4 General Purpose Inverter,MY SHOP,ABB ACS580-01-026A-4 General Purpose Inverter

Description

ABB ACS580-01-026A-4 General Purpose Inverter Official Product Description
1. Product Photo

ABB ACS580‑01‑026A‑4 General‑Purpose Variable‑Frequency Drive Detailed Specification

2. Model Code Explanation

ACS580:ABB all‑round general‑purpose AC drive, suitable for both variable‑torque and constant‑torque industrial loads. 01:Wall‑mount complete unit, standard IP21 protection class. 026A:Light‑duty rated output current 25 A; heavy‑duty rated output current 17 A. 4:Three‑phase supply voltage 380~480 V, 50/60 Hz. Light‑duty matched for 11 kW three‑phase motor; heavy‑duty matched for 7.5 kW three‑phase motor. Frame size R2.

3. Electrical Rated Parameters

Input Power Specifications

Three‑phase AC 380480 V, voltage tolerance +10%/‑15%, input frequency 4763 Hz. Built‑in swinging input reactor for grid harmonic suppression, complying with EN61000‑3‑12. Rated power factor 0.98, rated operating efficiency 98 %, meets IE2 energy‑efficiency standard.

Output Electrical Specifications

Three‑phase output voltage 0480 V, adjustable output frequency range 0500 Hz.

  • Light‑duty continuous output current:25 A; 110 % overload for 60 seconds every 5 minutes.
  • Heavy‑duty continuous output current:17 A; 150 % overload for 60 seconds every 5 minutes.
  • Peak output current:37.5 A.

Supports three motor types: asynchronous induction motors, permanent‑magnet synchronous motors and synchronous reluctance motors.

Motor Control Performance

Dual control modes: scalar V/F control and sensorless vector control. Vector‑control torque step response<10 ms; static speed accuracy up to 20 % of motor rated slip. Switching frequency adjustable from 2 kHz to 16 kHz, factory default 4 kHz. Switching frequency automatically reduces under high‑temperature operation for noise reduction and overheat protection.

Standard Built‑in Features

Built‑in Class C2 EMC electromagnetic filter; built‑in swinging harmonic input reactor. R2 frame equipped with integrated brake chopper for direct external braking‑resistor connection. Dual‑channel STO Safe‑Torque‑Off function, safety level SIL3. On‑board RS485 Modbus RTU communication interface. USB debugging port on control panel. Circuit boards with full conformal three‑proof coating. Separate hot‑cold independent air‑duct design; cooling airflow does not pass through circuit boards. Standard ACS‑AP‑I Chinese basic control panel.

Environmental & Installation Parameters

Protection class IP21. Overall dimensions:H473 mm × W125 mm × D229 mm. Net weight:6.6 kg. Vertical wall‑mount installation. Full‑load output within‑10℃ ~ +40℃ ambient temperature; derating required for 40℃ ~50℃. Full‑rated output up to 1000 m altitude; 1 % power derating per additional 100 m above 1000 m. Operating relative humidity:5 %‑95 %, no condensation, no corrosive conductive dust. Certifications:CCC, CE, UL, RoHS, SIL3; compliant with EN61800 low‑voltage drive standard.

4. Hardware I/O Terminal Configuration

6 digital input channels, passive inputs, PNP/NPN universal, internal 24 VDC power supply. Functions:start‑stop, multi‑speed switching, fault reset, PID mode switch, fire‑forced‑run signal input. 2 analog input channels, adaptive for 010 V voltage and 420 mA current signals, compatible with pressure, temperature and level transmitters. 2 analog output channels, supporting 010 V /420 mA output, transmitting motor frequency, output current, speed and torque data. 3 relay output channels, passive contacts 250 VAC/8 A, independently output running, fault and alarm signals. Dual‑channel STO safety terminals for hardware‑level motor torque cut‑off. On‑board RS485 communication terminal for direct connection with PLC, HMI and host SCADA systems.

5. Built‑in Standard Functions

Fan & Pump‑Dedicated Functions

SPFC multi‑pump rotation control, supporting automatic rotation start‑stop of up to 7 pumps to equalize equipment wear. Dual built‑in PID closed‑loop regulation with sleep‑wake‑up energy‑saving logic:low‑load low‑frequency sleep; automatic wake‑up when process pressure falls below set threshold. Fire override mode:all fault protections are suppressed and fans run at full speed upon trigger. S‑curve soft‑ramp acceleration/deceleration to suppress water‑hammer impact. Built‑in anti‑surge and flow‑compensation algorithms.

General‑Purpose Industrial Control Functions

Sensorless vector control delivers stable high low‑speed torque for heavy‑duty applications such as conveyors and agitators. 7‑step multi‑speed operation via digital‑input gear switching. Linear / S‑curve acceleration‑deceleration selectable; ramp‑time range:0.1 s‑3000 s. 20 sets of one‑click application macros covering general operation, 3‑wire start‑stop, PID constant‑pressure water supply, multi‑pump linkage, fire fans, conveyors and food‑processing machinery. Built‑in adaptive logic programming for custom control logic, reducing requirements for small auxiliary PLCs. Automatic motor identification precisely matches motor parameters and improves control accuracy. Stores up to 50 historical fault records. Supports DriveTune Bluetooth APP wireless debugging and parameter copying. Intelligent thermostatically‑controlled fan on‑demand start‑stop reduces power consumption and noise and extends fan service life. Built‑in energy‑calculation function for real‑time power‑saving and carbon‑emission‑reduction statistics.

Protection System

Instant pulse blocking for output overcurrent, phase‑to‑phase short‑circuit and earth short‑circuit. Graded alarm and shutdown for DC‑bus overvoltage / undervoltage. Heatsink pre‑alarm and overtemperature shutdown protection. Electronic thermal overload simulates motor overheating protection. Supports external PTC thermistor for motor‑winding temperature monitoring. Input phase‑loss, voltage‑unbalance and output earth‑fault monitoring. Complete protection logic:power‑fail buffered stop, STO safety cut‑off, cooling‑fan‑fault detection and inlet‑air‑temperature pre‑warning.

6. Original Optional Accessories

Control Panels

ACS‑AP‑I Chinese basic control panel (standard). ACS‑AP‑W Bluetooth graphic panel for wireless debugging. Panel extension cables for remote wall‑mount panel installation.

Communication Expansion Modules

FPBA‑01 Profibus‑DP module, FENA‑21 Ethernet/IP module, FDCO‑01 DeviceNet module, FPNO‑01 PROFINET module.

Braking Components

Power‑matched braking resistors. Built‑in chopper inside the drive; only external resistors required for fast‑stop and inertia‑load applications.

Filter & Reactor Accessories

Input line reactor, output dv/dt filter for long motor‑cable applications.

Mounting & Protection Accessories

IP55 outdoor enclosure kit, DIN‑rail mounting bracket, DPMP‑03 panel‑mount base.

Debugging Tools

MFDT‑01 FlashDrop parameter copier, Drive Composer PC debugging software.

7. Core Product Advantages

Independent hot‑cold‑separated air‑duct:cooling airflow does not touch circuit boards. Circuit boards with enhanced three‑proof conformal coating for extended service life in dusty and humid environments. Key functions pre‑integrated:C2 EMC filter, harmonic reactor, R2‑frame brake chopper, SIL3 STO safety function and Modbus communication without extra purchasing, simplifying selection and procurement. Dual scalar‑and‑vector control for variable‑torque (fan/pump) and constant‑torque (conveyor/agitator) loads for cross‑industry versatility. Compatible with asynchronous, permanent‑magnet and synchronous‑reluctance motors for PM‑motor retrofit projects. Complete digital‑operation‑maintenance ecosystem:Bluetooth panel, DriveTune mobile APP and PC software support wireless data reading, fault prediction and online parameter modification. Wide grid‑voltage tolerance for unstable‑voltage sites such as factories and construction sites. Modular expandable design; field‑bus, I/O and encoder modules can be retrofitted without replacing the whole drive.

8. Typical Application Scenarios

HVAC:cooling‑tower fans, fresh‑air/exhaust equipment, central‑air‑conditioning circulating pumps, fire‑smoke‑exhaust fans. Building water supply:secondary constant‑pressure water‑supply pumps, domestic pressure‑stabilizing pumps, sewage circulating transfer pumps. Light industry:belt conveyors, agitators, packaging machinery, extruders, centrifuges. Food & pharmaceutical:compressors, drying fans, filling‑line drive equipment. Process cooling:chiller circulating pumps, dust‑removal fans, laboratory constant‑temperature‑equipment drives.